Skip to main content
Home Air Filters Nitrogen Generators Liquid Nitrogen Plants Air Dryers Replacement Elements About Us Contact Blog 💬 WhatsApp Us
Omega Air Authorised Dealer — India & SAARC

Omega Air Filter Elements
India — Genuine, In Stock, Delhi

Genuine Omega Air replacement filter elements for AAF, BF, HF and CHP series compressed air filters. Available in all five grades — P, R, M, S and ACS — ISO 8573-1 certified. As the authorised Omega Air dealer for India, we supply from Delhi stock with pan-India delivery in 24–72 hours.

5 Element Grades
6 Filter Series
Authorised Dealer
ISO 8573-1 Certified
💬 WhatsApp Enquiry 📞 +91-9810070303
AAF — 16 bar Screwed BF — 16 bar Flanged HF — 50 bar CHP — 420 bar VAC — Vacuum
Authorised Omega Air Dealer
Nitrogenium is the authorised Omega Air dealer for India and SAARC. All elements supplied are genuine Omega Air product — not copies — with manufacturer traceability and ISO 8573-1 certification.
6
Filter Series
5
Element Grades
420
Max bar (CHP)
4h
Quote Turnaround
AAF Series
Screwed BSP connection — 16 bar — 10 to 2,760 Nm³/h
16 bar max BSP ½" – 3" ISO 8573-1

The AAF is Omega Air's most widely installed compressed air filter series — screwed BSP connections from ½" to 3", flows from 10 to 2,760 Nm³/h at 7 bar, max working pressure 16 bar. Used across general manufacturing, automotive, food & beverage, and pharmaceutical applications. Available in all five filtration grades.

Grade Rating Filtration ISO 8573-1 Typical Use Enquire
P 3 µm General particulate removal Class 3 (solid) Pre-filter, general use
R 1 µm Fine particulate removal Class 2 (solid) Pre-filter for coalescing stage
M 0.1 µm Coalescing — oil mist & water aerosols Class 2 (oil) General coalescing
S 0.01 µm High-efficiency coalescing Class 1 (oil) Food, pharma, electronics, N₂ gen
ACS Activated carbon Oil vapour, hydrocarbons, odours Class 1 (vapour) Food contact, breathing air, painting
Flow range: 10–2,760 Nm³/h at 7 bar  |  Connection: BSP ½" to 3" screwed  |  Max pressure: 16 bar  |  Temp: up to 60°C
BF Series
Flanged connection DN80–DN300 — 16 bar — 1,680 to 31,400 Nm³/h
16 bar max DN80–DN300 High Flow

The BF series is Omega Air's high-flow flanged filter — designed for large compressor rooms and central compressed air systems. Flanged connections DN80 to DN300, flow rates up to 31,400 Nm³/h at 7 bar, max 16 bar working pressure. Ideal for steel plants, cement factories, large automotive plants and utility air systems.

Grade Rating Filtration ISO 8573-1 Enquire
P3 µmGeneral particulateClass 3 (solid)
R1 µmFine particulateClass 2 (solid)
M0.1 µmCoalescing — oil mistClass 2 (oil)
S0.01 µmHigh-efficiency coalescingClass 1 (oil)
ACSCarbon bedOil vapour & odourClass 1 (vapour)
Flow range: 1,680–31,400 Nm³/h at 7 bar  |  Connection: Flanged DN80, DN100, DN125, DN150, DN200, DN250, DN300  |  Max pressure: 16 bar
HF Series
High pressure screwed BSP — 50 bar — 71 to 2,760 Nm³/h
50 bar max BSP ½" – 1½" High Pressure

The HF series handles high-pressure compressed air up to 50 bar — used in PET bottle blowing, tyre industry, high-pressure tool applications and pneumatic testing rigs. Screwed BSP connections, flow rates 71 to 2,760 Nm³/h. Available in M, S and ACS grades for critical downstream filtration.

Grade Rating Application Enquire
P3 µm particulatePre-filtration for HF systems
M0.1 µm coalescingPET blowing, tyre press, HP tools
S0.01 µm high-efficiencyCritical HP applications — ISO Class 1
ACSActivated carbonHP vapour removal
Flow range: 71–2,760 Nm³/h at 7 bar  |  Connection: Screwed BSP  |  Max pressure: 50 bar  |  Typical use: PET blowing, tyre industry, HP testing
CHP Series
Very high pressure screwed BSP — 100 to 420 bar — 40 to 715 Nm³/h
Up to 420 bar Ultra-HP

The CHP series is Omega Air's ultra-high-pressure filter range — up to 420 bar working pressure. Used in CNG (compressed natural gas) filling stations, breathing air panels, hyperbaric applications, hydraulic test rigs and specialty gas systems. Robust steel construction with screwed connections rated to ATEX and pressure vessel standards.

Pressure Range Flow (Nm³/h) Grade Available Typical Use Enquire
100 bar40–715M, S, ACSHP compressor downstream
200 bar40–500M, S, ACSCNG, breathing air, diving
420 bar40–300M, S, ACSUltra-HP specialty, military
⚠️ High-pressure application: CHP filter elements must be selected in consultation with our technical team. Share your system pressure, flow rate and application — WhatsApp us at +91-9810070303.
P-VAC & M-VAC Series
Vacuum filter elements — P-VAC up to 345 Nm³/h  |  M-VAC (medical) up to 787 Nm³/h
Vacuum Medical Grade

Omega Air's vacuum filter series — P-VAC for general industrial vacuum applications (1.25–345 Nm³/h, BSP + flanged connections) and M-VAC for medical and dental vacuum systems (1.25–787 Nm³/h, compliant with HTM 02-01 and ISO 7396-1). Elements available in M (coalescing) and bacterial filter grades.

Series Flow Range Connection Application Enquire
P-VAC1.25–345 Nm³/hBSP & FlangedIndustrial vacuum, suction cups, clamping
M-VAC1.25–787 Nm³/hBSP & FlangedHospital, dental, medical vacuum systems
Genuine Omega Air — Authorised Dealer

Need a specific Omega Air element? We stock or source within 24 hours.

Share your filter model (e.g. AAF-030) and required grade. We confirm part number, price and availability immediately.

💬 WhatsApp Now 📞 +91-9810070303 Send Enquiry →
Element Selection Guide

Which Omega Air Element Grade Do You Need?

Omega Air elements are installed in a filtration train — typically 2 to 3 stages depending on the downstream air quality requirement. Each grade removes a progressively finer class of contamination. Selecting the right grade for each position is essential for ISO 8573-1 compliance.

P — 3 µm Particulate
Stage 1 — Bulk solid removal

Removes rust, scale, dust and coarse particles ≥3 µm. Protects downstream coalescing elements from premature blocking. Used as first-stage pre-filter in most compressed air systems.

R — 1 µm Fine Particulate
Stage 1–2 — Fine solid removal

Removes finer particulates ≥1 µm including carbon dust from oil-lubricated compressors. Often installed between P and M grades to extend coalescing element life in high-contamination environments.

M — 0.1 µm Coalescing
Stage 2 — Oil mist removal

Removes liquid oil, oil mist and water aerosols down to 0.1 µm. Residual oil content ≤0.1 mg/m³. ISO 8573-1 Class 2 (oil). The most widely installed element in industrial compressed air systems.

S — 0.01 µm High-Efficiency
Stage 3 — ISO Class 1 oil

Removes ultra-fine oil mist and water aerosols to 0.01 µm. Residual oil <0.01 mg/m³. ISO 8573-1 Class 1 (oil). Required for food, pharma, electronics, nitrogen generators and breathing air applications.

ACS — Activated Carbon
Stage 4 — Vapour & odour removal

Adsorbs oil vapour, hydrocarbons and odours. Residual oil vapour <0.003 mg/m³. ISO 8573-1 Class 1 (vapour). Essential for food contact air, breathing air, paint spraying and any application sensitive to hydrocarbon contamination.

Technical Specifications

Omega Air Filter Series — Technical Comparison

Series Connection Max Pressure Flow Range Grades Typical Use
AAFScrewed BSP ½"–3"16 bar10–2,760 Nm³/hP, R, M, S, ACSGeneral industrial
BFFlanged DN80–DN30016 bar1,680–31,400 Nm³/hP, R, M, S, ACSLarge plants, utilities
HFScrewed BSP50 bar71–2,760 Nm³/hP, M, S, ACSPET blowing, tyre industry
CHPScrewed BSP100–420 bar40–715 Nm³/hM, S, ACSCNG, breathing air, diving
P-VACBSP & FlangedVacuum1.25–345 Nm³/hMIndustrial vacuum systems
M-VACBSP & FlangedMedical vacuum1.25–787 Nm³/hMedical gradeHospital, dental vacuum
Application Sets

Recommended Element Combinations by Application

🏭 General Manufacturing
Pneumatics, tools, actuators, general instrumentation
Element set: P + R + M
🎨 Paint & Coating
Spray painting, powder coating, surface treatment
Element set: P + M + ACS
🍎 Food & Beverage / Pharma
Product contact air, filling, packaging, clean rooms
Element set: P + S + ACS
🔬 Electronics / Semiconductors
PCB assembly, SMD, cleanroom air supply
Element set: R + M + S
⚗️ Nitrogen Generator Feed
PSA nitrogen generator compressed air inlet
Element set: P + M + S
🏥 Medical / Breathing Air
Hospital, dental, breathing air panels
Element set: M + S + ACS (M-VAC for vacuum)
Why Buy Omega Air Elements from Nitrogenium

The Authorised Omega Air Dealer for India & SAARC

🏅
Authorised Dealer — Genuine Product
Not a copy or compatible — every element we supply is genuine Omega Air product with full manufacturer traceability and warranty support.
🏆
ISO 8573-1 Certified
All Omega Air elements are independently tested and certified to ISO 8573-1. You receive test certificates on request.
📦
Delhi NCR Stock — Fast Dispatch
High-turnover AAF and BF series elements stocked in Delhi. Orders placed before 2 PM dispatched same day. Pan-India delivery in 3–5 days.
🔁
Parker Cross-Reference Available
Omega Air ODHE series elements are certified cross-references for Parker Domnick Hunter Oil-X Evolution housings — same performance, direct drop-in fit.
🧾
GST-Compliant Invoicing
Registered supplier — GST invoice with correct HSN codes for all compressed air filter elements. Suitable for maintenance department PO processing.
🔧
Technical Support
Our engineers help you select the correct filter series, element grade and replacement interval. Free pre-purchase consultation.
Frequently Asked Questions

Omega Air Filter Elements — FAQ

What Omega Air filter series do you supply elements for? +
We supply genuine Omega Air filter elements for all major series: AAF (screwed BSP, 16 bar, 10–2,760 Nm³/h), BF (flanged DN80–DN300, 16 bar, up to 31,400 Nm³/h), HF (50 bar high pressure, screwed BSP), CHP (ultra-high pressure up to 420 bar), P-VAC (industrial vacuum) and M-VAC (medical vacuum). If your filter model is not listed, WhatsApp us the model plate details and we will identify the correct replacement element.
Are Omega Air elements interchangeable with Parker Domnick Hunter? +
Yes — Omega Air's ODHE series elements are engineered as direct cross-references for Parker Domnick Hunter Oil-X Evolution filter housings. ODHE elements are dimensionally identical to Parker cartridges and certified to the same ISO 8573-1 class. They fit all existing Parker Oil-X Evolution housings without modification. This is not a generic "compatible" product — it is an Omega Air engineered replacement with its own test certification. Share your Parker part number and we will confirm the ODHE cross-reference immediately.
Which element grade should I use — M or S? +
M grade (0.1 µm, ISO Class 2 oil) is suitable for general industrial use — pneumatics, tools, actuators, spray painting, textile machinery. S grade (0.01 µm, ISO Class 1 oil) is required for food and beverage product contact, pharmaceutical cleanrooms, electronics manufacturing, nitrogen generators and breathing air. If your process requires the air to touch food, medicine or electronics — specify S grade. If in doubt, WhatsApp us with your application and we will recommend the correct grade.
How do I identify my Omega Air filter model? +
The filter series and size are stamped on the filter housing nameplate (e.g. AAF-030 = AAF series, size 030, which flows ~300 Nm³/h at 7 bar). The element grade (P, R, M, S, ACS) is printed on the element label. If the label is worn, look for the colour of the end-cap: typically green/grey = particulate (P/R), grey/white = coalescing (M/S), black = carbon (ACS). Send us a photo on WhatsApp and our engineers will identify the part within the hour.
What is the replacement interval for Omega Air filter elements? +
Omega Air recommends replacing coalescing and particulate elements (P, R, M, S grades) every 12 months or 4,000 operating hours, whichever comes first. ACS activated carbon elements should be replaced every 6 months as the carbon bed saturates regardless of pressure drop. In Indian conditions (high ambient dust, high humidity), we recommend checking elements at 8–9 months. A rising differential pressure gauge or red indicator is a reliable sign the element needs immediate replacement.
Do you supply Omega Air elements for BF flanged filters in India? +
Yes — BF flanged filter elements (DN80 to DN300) are available through Nitrogenium for all grades (P, R, M, S, ACS). BF series elements are used in large compressor rooms and utility air systems in steel plants, cement factories, large automotive plants and power utilities. Lead time is typically 5–10 business days for large BF elements depending on DN size. Contact us with your BF filter DN size, grade, and required quantity for a quotation.
Related Products & Resources

Also Available from Nitrogenium

New Filter Housings
Omega Air Filter Systems
AAF, BF, HF, CHP — complete filter units
Compatible Elements
Parker Domnick Hunter
AO, AA, ACS — ODHE cross-reference
Compatible Elements
Ultrafilter / Donaldson
PE, FF, MF, SMF, AK grades
Compatible Elements
Atlas Copco
DD, PD, UD, QD — Standard & Plus
Related Product
Nitrogen Generators
Omega Air PSA nitrogen systems
All Brands
Replacement Elements Index
Parker, Ultrafilter, Atlas Copco, Kaeser + Omega Air